What are the repair parts for the DTU363DS, series F6 (may be shown as F06)?
Issue:
Design Repair parts

Product Line:
Double Throw Safety Switch

Resolution:
The repair parts for the DTU363DS, series F6 (F06) are as follows. No other parts are available.
-Line Base - 4056624750 (1 each upper and lower; arc suppressor and wire assembly not included)
-Line Base mounting screws - 4020515101 (3 required per line base)
-Arc Suppressor Assembly - 4056635550 (1 required per line base)
-Arc Suppressor mounting screw - 4020514501 (1 required per arc suppressor)
-Wire Assembly- 4056780050 (for A and B phase only; includes cable factory connected mechanical lug at one end and a crimped connector at the other end)
-Wire assembly-4056780051 (for C phase only; includes cable factory connected mechanical lug at one end and a crimped connector at the other end)
-Line and Load Lug Assembly - 4025101851 (3 per base assembly)
-Line and Load Lug mounting screw - 4020514202 (1 required per lug)
-Ground Lug(s) - 4025101851 (per lug)
-Ground Lug mounting screw - 4020513503 (1 per ground lug)
-Switch Mechanism - 4056646950 (1 each for upper and lower)
-Linkage Assembly - 4056665350
-Linkage Assembly mounting screws that go into the side of the enclosure- 2194900001 (3 required; also replace the mounting screw rubber gaskets)
-Linkage Assembly mounting screw rubber Gaskets - 4050322802 (3 required)
-Linkage Assembly mounting screw that go into the back mounting pan inside the switch - 2142217101 (4 required)
-Handle - 4056688850
-Lockplate - 4056689501
-Lockplate mounting screws - 2194900001 (2 required; also requires rubber gasket)
-Lockplate mounting screw rubber gasket - 4050322802

Schneider Electric USA

Explore more
Product:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Product:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings