Video: How do I change from ramp stop to freewheel stop on the ATV61 and ATV71 drives?

Resolution:

  • Go into the Application menu 1.7
  • Enter Stop configuration
  • Enter " type of stop"
  • Change SST (type of stop) value to NST and enter.

Additional resources (attached):  ATV71 programming manual and ATV61 programming manual.