Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
ION EEM: Unable to Export a Report As PDF or Excel document

Goals and Symptoms

Symptoms:
When you try to Export a report in EEM as a PDF or Excel document as shown below:

image.png


this screen pops up for a moment and then goes away:

image.png

Causes and Fixes

Fix:

Please check the Internet Explorer's Internet Options -> Security settings and make sure that:

1) pop-ups are not being blocked for the ION EEM website

2) the ION EEM website is added to the trusted sites list

3) all of the options under the Downloads section of the security settings in the trusted sites zone are active as shown below:

image.png


Doing all of these things should allow the reports to download as a PDF or Excel document.

Workaround:
Another quick temporary workaround if the issue continues to occur is to hold down the CTRL button while making the selection in Internet Explorer. Holding down CTRL will always bypass any blocking that Internet Explorer is doing automatically.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings