Our Brands

Impact-Company-Logo-English Black-01-177x54

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
How to convert a 9001 Type K/SK momentary push button operators to maintained?

Issue:
Is there a module to make the momentary 9001 type K or SK push button operators to maintained?

Product Line:
Class 9001 Type K/SK Momentary Pushbuttons

Environment:
Class 9001 Type K/SK momentary push button operators with maintained contacts.

Cause:
Help clarify how to order a push on/ push off operator.

Resolution:
Use the 9001K85 Push On/Push Off module to convert the momentary push button to maintained. Be aware that they must use the early closing NO contacts like the 9001KA4 or 9001KA6

Schneider Electric USA

Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings