For multi axes synchronization in LMC058, offset regulation will happen on the fly.
FB MC_Phasing is available, but it only works for electronic gearing.
In electronic cam , FB MC_Phasing will interrupt the cam running so a logical encoder is the solution.
See details in the attachment.

Schneider Electric USA

Attachment(s)
Synchronization offset in SoMachine.pdf [170.76 KB]