Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
Vijeo Designer cannot run simulation. Error: "Could not start runtime. Make sure runtime is installed."
Issue:
Unable to launch the Vijeo Designer simulation mode.

Product Line:
Vijeo Designer (all versions)

Resolution:
One possible cause for this error is if there is a file or folder at C:\ named "Program". Typically this file or folder is locked and cannot be deleted normally. If one exists, reboot your PC in safe mode to either rename it or delete it.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings