Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
How to reverse the rotation of a Lexium ILS motor
Issue:
Reverse the rotation of an ILS motor

Product Line:
Lexium ILS motor

Resolution:
To reverse the direction of the ILS motor, you need to change the rotation parameter:
In LexiumCT, the parameter is Motion.invertDir (0 = clockwise 1 = counterclockwise)
You can also access this parameter by writing to its CANOpen address 28:6
The 2 cables needed to connect with LexiumCT are VW3L1T000R30 and TCSMCNAM3M002P

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings