Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
How to save and load current values in a .csv file using SoMachine/Machine Expert - Basic?

You can save/load the current values in a .cvs file using the following method:

Save Data:

  • Go to Commissioning tab
  • Select Controller Memory Management
  • In the Destination field, select the folder where you want to save the current values
  • Then select which range of %M or %MW you want to save
  • And finally press the button "Backup from Controller"


-


Restore data:

  • Select the option Restore to Controller
  • Select the .csv file in your PC
  • Press the button "Restore to Controller"

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings