Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
Video: How to reset the Vijeo Designer layout back to default?
Issue:
Looking for a way to reset my Vijeo Designer windows. The Windows are all scattered.

Product Line:
Vijeo Designer (all versions)

Resolution:
Sometimes when you move the windows and panes around in Vijeo Designer, you may want to move them back to default. The easiest way to do so is with the following procedure:

Simply shutdown Vijeo Designer, open up REGEDIT and delete the following key:
-For Vijeo Designer v6.2 SP8 or older, delete:
HKEY_CURRENT_USER\Software\Schneider Electric\Vijeo-Designer62

-For Vijeo Designer v6.2 SP9 or newer, delete:
HKEY_CURRENT_USER\Software\Schneider Electric\Vijeo-Designer62B

After you delete that, restart Vijeo Designer.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings