Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
Connexium Network Manager returns PSM error for a Red Lion device.

Issue
Connexium Network Manager returns PSM error for a Red Lion device.

Product Line
Connexium Network Manager 2.0

Environment
Windows 10

Resolution
Running Connexium Network Manager on a network that contains any 'N-Tron Red Lion' devices could result in a PSM
error getting returned in the logging window.  The device will appear in the network diagram as a switch.

Typically, this should not be a problem but if it does occur, the reason is because the Connexium Network Manager
does not support any Red Lion devices.

The error is getting returned and the device is represented as a switch because a PSM (Product Specific Module) file
for the device cannot be found.

There is no method available for the user to update Connexium Network Manager 2.0 with a new PSM file.  New PSM files
can only be created by Engineering.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings