Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
ENM installer fails on Check Database Maintenance "Invalid User Credentials"

Issue:
ENM  installer Fails on "Check Database Maintenance  "Invalid User Credentials" as shown below

error

Product Line:
Event Notification Module 8.3.x

Environment:
Distributed instance of ENM
Standalone instance of ENM

Cause:
The ENM installer fails with invalid user credentials when a local Windows admin account is not detected.

Resolution:
Need to use a Local Windows Admin account associated with the machine in which ENM is being
installed. The username and password credentials will be verified.
Note: A Domain admin is not supported configuration due to the great amount of variation in
possible Domain Rule/Rights.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings