Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
What can I do if the tag is not detected properly in Ecostruxure Augmented Operator Advisor?

Follow these rules when using tags:

  • Place the tag on a solid flat surface or on a window.
  • Do not use a tag in an environment with a grill or a mesh: the detection can be very slow or impossible, as the software will have difficulty differentiating between the tag and the grill/mesh.
  • Reference photos must be taken directly in front of the tag. The photo plane must be parallel to the tag plane for best results.
  • The detection camera plane must be also parallel to the tag plane. If a tag is placed at the top of a scene, consider tilting the tag downward to respect this parallelism. Any deviation from parallel of this photo will reduce the probability of tag detection.
  • When identifying the tag placement in the images, use the four corners of the tag itself, as indicated in green here:

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings