Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
How to avoid a HALT on Simulator on Win 7 ?
Issue
Some application of Unity Pro Simulator is not working. After a RUN, the application goes to HALT.

Product Line
Unity Pro 13.1

Environment
Windows 7 SP1

Resolution
To avoid this wrong behavior, you have to disable AVX support. You can do that by running this command from an elevated command prompt and then rebooting:
bcdedit /set xsavedisable 1

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings