Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
How to manage the camera application in AOA V2.6 application of Galaxy S20+?
1.    Issue
In Galaxy S20+, there is an issue with camera management. It created an issue during the initialization of camera application.
2.    Product Line
Galaxy S20+ mobile device, Ecostruxure Augmented Operator Advisor.
3.    Environment
EAOA V2.6, Android(S20+)
4.    Resolution
In the V2.6, camera management has been improved. But unfortunately, it created a regression on some not officially supported devices. This will be fixed in a future version(V2.6.1), but in the meantime, we need to do the below workaround for AOA V2.6.
In the tablet/phone, there is a “Settings.json” file in the “Android/data/com.schneiderelectric.AugmentedOperator” folder.
Edit it, find the “UseCameraNativePlugin” key and set its value to False, like below:

{
"key": "UseCameraNativePlugin",
"value": "False"
},
Save the file, start the app and it should be OK.

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings