Is there a longer adjustable length lever arm than a 9007HA1 for a 9007 type C limit switch ?
Issue:
Adjustable Lever Arms for 9007 Type C Limit Switches

Product Line:
Limit Switches

Environment:
9007 Type C switch

Resolution:
Use a 9007S9 hub, 9007R16 or R17 clamp for rod or keystock, and 9007R18 or R19 or R20 roller per Digest 172 pp. 19-7 and 19-17 . 1/4`` keystock or 3/16`` rod needed may be cut to the desired length. The rod or keystock is not supplied by Sq D.