Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
What components are included in the PM8000 hardware kits?
Issue
What is included in the PM8000 hardware kits?
Product Line
PM8000 Series Meters:

Environment
PM8000 series Power Meter hardware kit components

Resolution
Note: Purchase the correct PM8000 Kit.  You cannot purchase the single components from the kit.

METSEPM8000SK        Voltage and current sealing kit
METSEPMAK                Mounting adapter kit for remote display and DIN meter
METSEPM8HWK          PM8000 series input connector, CT screws and panel mounting hardware, Hardware Kit Replacement
METSEPM8RDHWK     Mounting & connecting hardware kit for remote display PM89RD
Breakdown of components in the PM8000 hardware accessory kits:
DescriptionComponent Qty
METSEPM8000SK
METER SEALING KIT, PM8000/ION7400 - Welmec Ver1
CURRENT INPUT TERMINAL GUARD, PM80001
SEAL, VOLTAGE AND PSU INPUTS, PM8XXX1
DescriptionComponent Qty
METSEPM8HWK
PLUG, 2 PIN, 7.62 PITCH, BLACK PSU INPUT CONNECTOR1
PLUG, 4 PIN, 7.62 PITCH, BLACK VOLTAGE INPUT CONNECTOR1
PLUG, 2 PIN, 5.08 PITCH, BLACK KY INPUT CONNECTOR1
PLUG, 6 PIN, 5.08 PITCH, BLACK DIG IN CONNECTOR1
PLUG, 4 PIN, 5.08 PITCH, BLACK RS485 CONNECTOR1
DescriptionComponent Qty
METSEPM8RDHWK
PM8XXX RMD GASKET FOR REARCASE1
RD96 RMD ACCESSORY ASSY1
DescriptionComponent Qty
METSEPMAK
METER ANSI KIT, PM80001
CABLE ASSEMBLY 2 X RJ25, 0.3 METER1
PM8000, ANSI KIT SUBASSY, BAGGED1
SCREW, 1/4-20 X 1/2, STEEL, ZINC PLATED, TRUSS, PH32
SCREW, M3.5 X .6 X 8MM, PAN HEAD, ZP, PH4
NUT, KEPS, 10-32, STEEL, ZINC PLATED4
WASHER, FLAT, .195" ID X .375" OD X .0404
END CLIP, TERM BLK, DIN RAIL, PLASTIC,W/LOCKING SCREW,42MM L2
INSERT, ANSI 4" Back-To-Back Adapter, PM80001
PLATE, ADPATER, ANSI 4 TO 30MM D1
RETRO-FIT ADAPTER, WEDGE1
DIN RAIL, PERF, 35mm X 7.5mm X 200mm1
ANSI 4 INCH ADAPTER BRACKET, ASSY1
GSKT, PNL, PM8000 RMD, ANSI 42
RETRO-FIT ADAPTER, PANEL GASKET2
0.3M NETWORK WIRE1

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings