Issue:
Needs Ethernet communication on the ATS48 or ATS22 solid state softstarters
Product Line:
ATS22, ATS48
Environment:
All
Cause:
NA
Resolution:
The ATS22 and ATS48 only support Modbus communication protocol.
Use a Gateway for Modbus - Ethernet IP conversion.
Consider the EGX150 - Link150 Ethernet Gateway or a device from a 3rd party such as ProSoft or AnyBus.
Please be aware that you cannot do I/O scanning on the ATS48 or the ATS22 soft starter.