You are currently viewing the content available in Vietnam. If you are looking for information for another region, please select the correct country from the top-left dropdown in the page and 'Navigate to Browse FAQs' in the Support menu.
Issue:
How to increase the torque out of a motor when running at lower speeds with an ATV312 drive
Product Line:
ATV312
Environment:
All
Cause:
More torque
Resolution:
First, verify that the motor data is correct in the drC menu. Then set UFt to L. In the SEt menu, increase UFr to provide higher torque output.
How to increase the torque out of a motor when running at lower speeds with an ATV312 drive
Product Line:
ATV312
Environment:
All
Cause:
More torque
Resolution:
First, verify that the motor data is correct in the drC menu. Then set UFt to L. In the SEt menu, increase UFr to provide higher torque output.