You are currently viewing the content available in Vietnam. If you are looking for information for another region, please select the correct country from the top-left dropdown in the page and 'Navigate to Browse FAQs' in the Support menu.
Issue:
Operating temperature range for the Altistart 22
Product Line:
ATS22, Altistart 22
Environment:
All models, all serial numbers.
Cause:
high or low ambient temperatures.
Resolution:
The standard current ratings for the ATS22 is based on an ambient temperature of 40C (104F).
The minimum operating temperature is -10C (14F). The maximum operating temperature is 60C (140F).
When operating above 40C (104F), the softstart needs to be derated by 2.2% for every degree Celsius above 40C (104F).
For example: ATS22D32S6U is 32A rated. For an ambient temperature of 50C (122F), derating is 22% (2.2 x 10). The 32A softstart rating becomes 24.96A (32A x 0.78 = 24.96).
Operating temperature range for the Altistart 22
Product Line:
ATS22, Altistart 22
Environment:
All models, all serial numbers.
Cause:
high or low ambient temperatures.
Resolution:
The standard current ratings for the ATS22 is based on an ambient temperature of 40C (104F).
The minimum operating temperature is -10C (14F). The maximum operating temperature is 60C (140F).
When operating above 40C (104F), the softstart needs to be derated by 2.2% for every degree Celsius above 40C (104F).
For example: ATS22D32S6U is 32A rated. For an ambient temperature of 50C (122F), derating is 22% (2.2 x 10). The 32A softstart rating becomes 24.96A (32A x 0.78 = 24.96).
Released for: Schneider Electric Vietnam


Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales enquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Centre
Find support resources for all your needs, in one place.