How to connect 2 cables with a Cable lug to one Altivar variable speed drive Power terminal?
See attached picture. Consider recommended cable cross-section mentioned in ATV installation manual, then selection of typical cable lug will not cause a problem. If you use lower cable crossection, due to shorter flat distance on cable lug a problem can occur.
Dimensions refer to ATV630C22N4 power terminals.