{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.

What is the difference between Utilization categories A and B in circuit...

Utilization categories According to IEC 60947-2, Utilization category of a circuit breaker shall be stated with reference to whether or not it is specifically intended for selectivity by means of an...

PowerLogic PM5000 Series (PM5100, PM5300, PM5500) Modbus Register List

Issue Register list for Modbus communication Product Line PM5110, PM5330, PM5340, PM5560, and PM5563 Environment Power Meter Communications Modbus Register List Cause PM5000 series register list is...

What is the meaning of the S**** suffix at the end of Lexium ILA, ILE, ILS...

There are custom made types of ILA, ILE, ILS Integrated drives for some Machine producers. The S**** suffix at the end of Lexium ILA, ILE, ILS reference determines type of customization. Contact your...

Biến tần hiển thị lỗi (nSt) nghĩa là gì?

Các nguyên nhân có thể khi trên màn hình biến tần hiển thị nSt là: nSt không phải là lỗi 1. Khi mở nguồn biến tần nhưng tiếp điểm chạy đã đóng sẵn, cần phải nhả tiếp điểm chạy ra rồi đóng lại thì sẽ...

Số hotline hỗ trợ kỹ thuật của Schneider Electric là gì?

Số hotline hỗ trợ kỹ thuật của Schneider Electric là: 1800585858 Ngoài ra khách hàng có thể gửi thông tin vào địa chỉ email: Customercare.vn@Schneider-electric.com

Dòng PLC TM218LDA40DRPHN nâng cấp lên dòng nào

Tương ứng có thể nâng cấp lên M221 hoặ M241 tuy nhiên cần lưu ý một vấn đề về chuyển đổi chương trình từ PLc cũ lên: 1. TM218 lên M221: TM218 dùng phần mềm SOMACHINE, M221 dùng phần mềm SOMACHINE...

Power Monitoring Expert - How can I delete a device and all of its data?

Issue A meter was installed into the Power Monitoring Expert (PME) or StruxureWare Power Monitoring (SPM) system and has been logging data, waveforms, and events for any length of time. For whatever...

ION Setup Offline Programming does not allow the assignment of digital and...

Issue ION Setup Offline Programming does not allow the assignment of digital and analog inputs and outputs Product Line ION Meters Environment ION Setup Cause ION Setup was designed with the ability...

Show more

Popular Video FAQsPopular Videos

video-thumbnail
video-thumbnail
video-thumbnail
video-thumbnail
video-thumbnail
video-thumbnail
video-thumbnail
video-thumbnail
video-thumbnail
Show more

Learn more through our Generic Knowledge FAQsGeneral Knowledge

Where is SEVN's warehouse?

South: DT 743, 1B Hamlet, Thuận An, Bình Dương North:ICD Tiên Sơn, TS9 street, huyện Tiên Du, Bắc Ninh

What is the selection criterion of Circuit Breakers for the Capacitor bank...

The selection should be done after derating the Circuit Breaker taking into consideration voltage variation and capacitors tolerances that could increase nominal current up to 1.5In. The Derating...