Category 0 is an uncontrolled stop by immediately removing power to the machine actuators.
Category 1 is a controlled stop with power to the machine actuators available to achieve the stop then remove the power when the stop is achieved.
Category 2 is a controlled stop with power left available to the machine actuators.
What are the different NFPA 79 stop categories?
Product Line:
Operating Mechanisms and Disconnect Switches
Environment:
Disconnect Switches
Resolution:
Category 0 is an uncontrolled stop by immediately removing power to the machine actuators.
Category 1 is a controlled stop with power to the machine actuators available to achieve the stop then remove the power when the stop is achieved.
Category 2 is a controlled stop with power left available to the machine actuators.