Does the LAD9R1 or LAD9R1V mechanical interlock fit the Pre TeSys LP1D and LC1D 9-32A type contactors?
Issue:
Pre TeSys LP1D and LC1D 9A - 32A accessory compatibility

Product Line:
IEC contactors and starters

Environment:
TeSys and Pre TeSys LC1D and LP1D

Cause:
Assembly/Fit/Compatibility

Resolution:
No, they do not. The Pre TeSys interlock part number is LA9D0902. It is now obsolete and no longer available.
The existing contactors rated 9-32A will need to be upgraded to the TeSys type to use the current style interlocks.