What is the difference between a “Normal Stop” and “Emergency Stop” versions of the XY2 cable pull switches?

Issue:
What is the difference between a “Normal Stop” and “Emergency Stop” versions of the XY2 cable pull switches?

Product Line:
Cable Pull Switches

Environment:
Machine Safety Products

Cause:
Product Selection

Resolution:
The Emergency stop versions have positive opening Normally Closed contacts that latch upon tripping (positive opening) and must be manually reset.

Normal stop versions are used where a momentary, non-emergency signal is required at any point along a cable. These devices have snap acting contacts and are non-latching devices.