{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.

Search FAQs

Can the standard full size Homeline branch circuit breakers be used in the new Homeline plug-on neutral load centers?

Issue:
Branch Circuit breakers used in the HOM Plug-On Neutral Load Centers

Cause:
Using standard Homeline branch breakers in PON LCs

Resolution:
Yes, the standard full size Homeline branch breakers can be used in the new Homeline plug-on neutral (PoN) load centers. This would include the old style GFI, AFI, and CAFI breakers with the white neutral pigtail wire (the pigtail wire on these breakers would still be wired to the neutral bar).

NOTE: The new plug-on neutral branch breakers CANNOT be used in the old style non-plug-on neutral Homeline load centers.

Schneider Electric Canada

Explore more
Range:
Explore more
Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.