Issue:
How to perform a Static Test on an Altivar Process drives.
Product Line:
Altivar Process Drive (ATV630, ATV930, ATV650, ATV950)
Resolution:
Checking The Input and Output Diode Bridges
This test is done using a digital multi-meter in diode test mode to check that the transistors and diodes are not short-circuited.
ALL TESTS ARE TO BE PERFORMED WITH ALL SOURCES OF POWER REMOVED FROM THE DRIVE
For Altivar Process Drive up to 25hp
- Range: ATV630... ATV930....
- U07M3 to D18M3 and U07N4 to D18N4
- Range: ATV650... ATV950...
- U07N4 to D18N4
- Drive uses all diodes on the Input and Output Diode Bridge.
- Instrument
- Use Digit-Meter with a diode scale
- Measurement
- Locate PA+ and PC- input on drive power terminals (should be close to your power connection terminals)
- Set meter to diode scale
- To measure Input diodes
- Place black on positive bus (PA+) and red on L1
- Get readings and then move to L2, and then L3
- When done swap red and black probes, and measure again between (PA+) to L1...L3
- Repeat the entire procedure measuring from PC- instead of PA+.
- Readings should be OL (should be above 1.0 and may continue to increase to OL if the meter is left connected long enough) in one direction and a low voltage reading the other way (Example 0.3v)
- To measure Output diodes
- Place black on positive bus (PA+) and red on T1
- Get readings and then move to T,2 and then T3
- When done swap red and black probes , and measure again between (PA+) to T1...T3
- Repeat the entire procedure measuring from PC- instead of PA+
- Readings should be OL in one direction and a low voltage reading the other way (Example 0.3v)
For Altivar Process Drive over 25hp
- Range: ATV630... ATV930....
- D22M3 to D75M3 and D22N4 to C31N4
- Range: ATV650... ATV950...
- D22N4 to D90N4
- Drive uses SCRs on the positive input bridge and diodes on the negative. For the Output Bridge its all diodes.
- Instrument
- Use Digit-Meter with an ohm and a diode scale
- Measurement
- Locate PA+ and PC- input on drive power terminals (should be close to your power connection terminals)
- To measure Input SCRs and diodes.
- Set meter to diode scale
- Place black on positive bus (PA+) and red on L1
- Get readings and then move to L2, and then L3
- When done swap red and black probes and measure again between (PA+) to L1...L3
- Readings should be 1.0 - OL in both directions (should be above 1.0 and may continue to increase to OL if the meter is left connected long enough).
- Set meter to diode scale
- Place black on positive bus (PC-) and red on L1
- Get readings and then move to L2 ,and then L3
- When done swap red and black probes and measure again between (PC-) to L1...L3
- Readings should be OL in one direction and a low voltage reading the other way (Example 0.3v)
- To measure Output diodes
- Place black on positive bus (PA+) and red on T1
- Get readings and then move to T2 ,and then T3
- When done swap red and black probes and measure again between (PA+) to T1...T3
- Readings should be OL in one direction and a low voltage reading the other way (Example 0.3v)
***
If this article does not answer your question, check out our FAQ database that has answers to more commonly asked questions: Frequently Asked Questions - Schneider Electric (se.com)
If this FAQ did not solve your issue, you can call us at 1-888-778-2733 Option 2 and then 4 or e-mail us at drive.products.support@se.com to create a case with our Technical Support Team.
If you are not located in North America, please contact your local Customer Care Center for assistance: Support | Schneider Electric Global (se.com)
Released for: Schneider Electric Canada




Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and en expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.