How can we help you today?

What is the replacement AC coil for the 8501XO and 8501XMO relays?

Issue:
In need of the AC coil replacement for the 8501 X & XM  series relays.

Product Line:
Industrial Relays

Environment:
NEMA Style AC Relays

Resolution:
Please see list below and check first if the part number is still active as some may already be obsolete.

Voltage60 Hz50 Hz
24 VAC9998X239998X24
110-115 VAC-9998X44
120 VAC9998X44-
208 VAC9998X519998X52
220 VAC9998X529998X53
240 VAC9998X53-
277 VAC9998X55-
380 VAC--
440 VAC-9998X62
480 VAC9998X62-
550 VAC-9998X65
600 VAC9998X65-