B814 Fuse Replacement

Goals and Symptoms

This resolution contains information which enables users to replace the internal 3AG Fast Acting Glass Body fuses that are in series with AS-B814-108 outputs.

Causes and Fixes

B814 fuses can be accessed by removing a plate which covers the option jumpers. In the illustration the plate has a Caution label on it. Four screws need to be removed to free the plate.

AS-B814-108

Fuse part numbers: Schneider 57-0083-000

        • Littelfuse 312007
          Bussman MTH7

Legacy KB System (APS) Data: RESL180177 V1.0, Originally authored by WeDa on 10/23/2006, Last Edited by WeDa on 10/23/2006