Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

You can visit our website in another country or region or go to our global website.
0
Logic controller, Modicon M221, 40 IO relay Ethernet

TM221CE40R

Environmental Data
Total lifecycle Carbon footprint
130
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
Yes
Use Again
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
No
Description
arrow2_down
This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This logic controller provides 24 discrete inputs and 16 relay ethernet outputs with 10bit input resolution, normally opened relay output. It is a Modicon logic controller with a rated supply voltage of 100V to 240V AC, an output voltage of 5V to 125V DC, 5V to 250V AC and an output current of 2A with sink or source input logic. This product requires minimal installation and offers tremendous versatility. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface and ethernet with RJ45 connector. It is a Modicon M221 controller with a network frequency of 50/60Hz, 256KB for internal variables RAM, user application and data RAM, a built-in flash memory of 256KB and a SD card memory capacity of 2GB. It is an IP20 rated product. Its dimensions are 160mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.456kg. This product is certified by CE, IACS E10, RCM, ABS, LR, DNV-GL, CSA, EAC and CULus. It meets EN/IEC 60664-1, EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. It supports DIN rail mount. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks
Specifications
arrow2_down
Main
Range of productModicon M221
Product or component typeLogic controller
[Us] rated supply voltage100...240 V AC
Discrete input number24, discrete input conforming to IEC 61131-2 Type 1
Analogue input number2 at 0...10 V
Discrete output typeRelay normally open
Discrete output number16 relay
Discrete output voltage5...125 V DC
5...250 V AC
Discrete output current2 A
Complementary
Discrete I/O number40
Maximum number of I/O expansion module7 (local I/O-Architecture)
14 (remote I/O-Architecture)
Supply voltage limits85…264 V
Network frequency50/60 Hz
Inrush current40 A
Maximum power consumption in VA70 VA at 100...240 V with max number of I/O expansion module
41 VA at 100...240 V without I/O expansion module
Power supply output current0.52 A 5 V for expansion bus
0.24 A 24 V for expansion bus
Discrete input logicSink or source (positive/negative)
Discrete input voltage24 V
Discrete input voltage typeDC
Analogue input resolution10 bits
LSB value10 mV
Conversion time1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed>= 15 V for input
Voltage state 0 guaranteed<= 5 V for input
Discrete input current7 mA for discrete input
5 mA for fast input
Input impedance3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
Response time35 µs turn-off, I2...I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time0 ms for input
3 ms for input
12 ms for input
Output voltage limits125 V DC
277 V AC
Maximum current per output common7 A
Absolute accuracy error+/- 1 % of full scale for analog input
Electrical durability100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency20 switching operations/minute with maximum load
Mechanical durability20000000 cycles for relay output
Minimum load1 mA at 5 V DC for relay output
Protection typeWithout protection at 5 A
Reset time1 s
Memory capacity256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
Data backed up256 kB built-in flash memory for backup of application and data
Data storage equipment2 GB SD card (optional)
Battery typeBR2032 or CR2032X lithium non-rechargeable
Backup time1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction0.3 ms for event and periodic task
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Maximum size of object areas8000 %MW memory words
255 %TM timers
512 %KW constant words
255 %C counters
512 %M memory bits
Realtime clockWith
Clock drift<= 30 s/month at 25 °C
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Counting input number4 fast input (HSC mode) at 100 kHz 32 bits
counter functionSingle phase
A/B
Pulse/direction
Integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface
Ethernet with RJ45 connector
Supply(serial)serial link supply: 5 V, <200 mA
Transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
Communication port protocolUSB port: USB - SoMachine-Network
Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Ethernet
Port Ethernet10BASE-T/100BASE-TX 1 port with 100 m copper cable
Communication serviceDHCP client
Modbus TCP client
Ethernet/IP adapter
Modbus TCP server
Modbus TCP slave device
Local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED per channel (green) for I/O state
1 LED (green) for SL
Ethernet network activity (green) for ACT
Ethernet network link (yellow) for Link (Link Status)
Electrical connectionremovable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
Maximum cable distance between devicesShielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
InsulationBetween input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
MarkingCE
Sensor power supply24 V DC at 250 mA supplied by the controller
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height90 mm
Depth70 mm
Width160 mm
Net weight0.456 kg
Environment
StandardsIEC 61131-2
UL 508
CAN/CSA C22.2 No. 213
IACS E10
ANSI/ISA 12-12-01
Product certificationsDNV-GL
EAC
ABS
cULus
LR
RCM
CE
UKCA
cULus HazLoc
Environmental characteristicOrdinary and hazardous location
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-2
4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3
1 V/m 2...2.7 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields30 A/m 50/60 Hz conforming to IEC 61000-4-8
Resistance to fast transients2 kV (power lines) conforming to IEC 61000-4-4
2 kV (relay output) conforming to IEC 61000-4-4
1 kV (I/O) conforming to IEC 61000-4-4
1 kV (Ethernet line) conforming to IEC 61000-4-4
1 kV (serial link) conforming to IEC 61000-4-4
Surge withstand2 kV power lines (AC) common mode conforming to IEC 61000-4-5
2 kV relay output common mode conforming to IEC 61000-4-5
1 kV I/O common mode conforming to IEC 61000-4-5
1 kV shielded cable common mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to IEC 61000-4-5
1 kV relay output differential mode conforming to IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
Resistance to conducted disturbances10 V 0.15...80 MHz conforming to IEC 61000-4-6
3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emissionConducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011
Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011
Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011
Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011
Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011
Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011
Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
Immunity to microbreaks10 ms
Ambient air temperature for operation-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
Pollution degree<= 2
Operating altitude0...2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
Shock resistance98 m/s² for 11 ms
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.09 cm
Package 1 Width14.183 cm
Package 1 Length21.085 cm
Package 1 Weight830.0 g
Unit Type of Package 2CAR
Number of Units in Package 212
Package 2 Height29.2 cm
Package 2 Width39.8 cm
Package 2 Length57.9 cm
Package 2 Weight11.04 kg
Unit Type of Package 3P12
Number of Units in Package 3144
Package 3 Height105.0 cm
Package 3 Width120.0 cm
Package 3 Length80.0 cm
Package 3 Weight145 kg
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Use Again
Repack and remanufacture
Dimensions Drawings
arrow2_down
Dimensions



Mounting and Clearance
arrow2_down
Mounting on a Rail



Direct Mounting on a Panel Surface


(1)
Install a mounting strip

Mounting Hole Layout



Mounting
Correct Mounting Position


Acceptable Mounting Position


Incorrect Mounting Position



Clearance



Connections and Schema
arrow2_down
Digital Inputs
Wiring Diagram (Positive Logic)


(*)
Type T fuse

Wiring Diagram (Negative Logic)


(*)
Type T fuse

Connection of the Fast Inputs


I0, I1, I6, I7


Relay Outputs
Negative Logic (Sink)


(*)
Type T fuse
(1)
The COM0, COM1, COM2 and COM3 terminals are not connected internally.
(2)
To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load
B
Sink wiring (negative logic)

Positive Logic (Source)


(*)
Type T fuse
(1)
The COM0, COM1, COM2 and COM3 terminals are not connected internally.
(2)
To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load
A
Source wiring (positive logic)


Analog Inputs



The (-) poles are connected internally.

Pin

Wire Color

0 V

Black

AN1

Red

0 V

Black

AN0

Red


Ethernet Connection


Pin N°

Signal

1

TD+

2

TD-

3

RD+

4

-

5

-

6

RD-

7

-

8

-



USB Mini-B Connection



SL1 Connection


SL1

N °

RS 232

RS 485

1

RxD

N.C.

2

TxD

N.C.

3

RTS

N.C.

4

N.C.

D1

5

N.C.

D0

6

CTS

N.C.

7

N.C*.

5 Vdc

8

Common

Common

N.C.: not connected

* : 5 Vdc delivered by the controller. Do not connect.



Performance Curves
arrow2_down
Derating Curves
Embedded Digital Inputs (No Cartridge)


X :
Ambient temperature
Y :
Input simultaneous ON ratio

Embedded Digital Inputs (with Cartridge)


X :
Ambient temperature
Y :
Input simultaneous ON ratio


Documents
arrow2_down
Software and Firmware
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Contact Support
  • Find our Offices
  • Need help? Start here
  • Where to buy
  • Careers
  • Company Profile
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Data Privacy
  • Cookies Policy
  • Terms of use
  • Change your cookie settings