Onze merken

Welkom op de website van Schneider Electric

Welkom op onze website.
		
Waarmee kunnen wij u vandaag helpen?
Where is the biometric switch information stored when using it with Vijeo Designer?
Issue
Where is the biometric switch information stored when using it with Vijeo Designer?

Product Line
Vijeo Designer
Harmony XBS5 Biometric Switch

Resolution
The encrypted fingerprint database is stored in Runtime and in the switch itself. When you configure fingerprints in your VJD application then download to the HMI, the fingerprint database is downloaded along with the project. At Runtime (on the HMI), when you connect the Biometric switch, the Runtime engine automatically downloads the fingerprint database to the device. When you add fingerprints in Runtime, the fingerprint data is stored in both Runtime and in the switch.

Schneider Electric Netherlands

Ontdek meer
Productfamilie
Ontdek meer
Productfamilie
  • Productdocumentatie
  • Software & firmware
  • Productselector
  • Productvervanging
  • Help- en Contact Center
  • Offerte aanvragen?
  • Openingstijden & adressen
  • Vind distributeur
  • Schneider Electric-community
  • Werken bij
  • Bedrijfsprofiel
  • Wangedrag melden
  • Toegankelijkheid
  • Newsroom
  • Investeerders
  • EcoStruxure
  • Vacature zoeken
  • Blog
  • Als eerste op de hoogte nieuws?
  • Dataprivacy
  • Cookiekennisgeving
  • Juridische informatie
  • Change your cookie settings