In Vijeo Designer, how do we record the date and time to a variable when a button is pressed?
Issue:
How to record a timestamp to a variable when a button is pressed?
Product Line:
Vijeo Designer (all versions)
Resolution:
To record the date and time when a button is pressed, you will need to create a script in that button that copies the system variables _Hours, _Minutes, _Seconds, _Year2, _Month, _Day to a string variable for time and a string variable for date.
Please see the example script below:
//-------------------------------------
//Script Created: Jan 25, 2016
//
// Description:
//
//-------------------------------------
// Replace this line with your script
String YearYY = _Year2.getStringValue();
String MonthMM = _Month.getStringValue();
String DayDD = _Day.getStringValue();
if(_Month.getIntValue() < 10)
{
MonthMM = "0" + _Month.getStringValue();
}
if(_Day.getIntValue() < 10)
{
DayDD = "0" + _Day.getStringValue();
}
DateString.write(YearYY + "/" + MonthMM + "/" + DayDD);
String HoursHH = _Hour.getStringValue();
String MinutesMM = _Minutes.getStringValue();
String SecondsSS = _Seconds.getStringValue();
if(_Seconds.getIntValue() < 10)
{
SecondsSS = "0" + _Seconds.getStringValue();
}
if(_Hour.getIntValue() > 11)
{
temp.write(_Hour.getIntValue() - 12);
HoursHH = temp.getStringValue();
TimeString.write(HoursHH + ":" + MinutesMM + ":" + SecondsSS + " pm");
}
else
{
TimeString.write(HoursHH + ":" + MinutesMM + ":" + SecondsSS + " am");
}
How to record a timestamp to a variable when a button is pressed?
Product Line:
Vijeo Designer (all versions)
Resolution:
To record the date and time when a button is pressed, you will need to create a script in that button that copies the system variables _Hours, _Minutes, _Seconds, _Year2, _Month, _Day to a string variable for time and a string variable for date.
Please see the example script below:
//-------------------------------------
//Script Created: Jan 25, 2016
//
// Description:
//
//-------------------------------------
// Replace this line with your script
String YearYY = _Year2.getStringValue();
String MonthMM = _Month.getStringValue();
String DayDD = _Day.getStringValue();
if(_Month.getIntValue() < 10)
{
MonthMM = "0" + _Month.getStringValue();
}
if(_Day.getIntValue() < 10)
{
DayDD = "0" + _Day.getStringValue();
}
DateString.write(YearYY + "/" + MonthMM + "/" + DayDD);
String HoursHH = _Hour.getStringValue();
String MinutesMM = _Minutes.getStringValue();
String SecondsSS = _Seconds.getStringValue();
if(_Seconds.getIntValue() < 10)
{
SecondsSS = "0" + _Seconds.getStringValue();
}
if(_Hour.getIntValue() > 11)
{
temp.write(_Hour.getIntValue() - 12);
HoursHH = temp.getStringValue();
TimeString.write(HoursHH + ":" + MinutesMM + ":" + SecondsSS + " pm");
}
else
{
TimeString.write(HoursHH + ":" + MinutesMM + ":" + SecondsSS + " am");
}
Gepubliceerd voor: Schneider Electric Netherlands
Ontdek meer
Productfamilie
Ontdek meer
Productfamilie
Hulp nodig?
Selecteer zelf het juiste product
Vind snel en eenvoudig de juiste producten en toebehoren voor uw toepassingen.
Offerte aanvragen
Dien uw aanvraag online in en een expert zal contact met u opnemen.
Verkooppunten
Vind eenvoudig de dichtstbijzijnde distributeur van Schneider Electric op uw locatie.
Help Center
Vind de antwoorden die u nodig heeft via bladeren door veelgestelde vragen over onderwerpen.