What is the reason for the error message "Error 1800: [Target] [target name] cannot find defined target machine" while downloading through Vijeo Designer ?
Below are the possible reason for this.
When using Serial or USB download, the error message appears due to one of the following:
- Target machine is OFF.
- Download cable is not connected to the defined port on the editor PC.
- Download cable connections are loose.
- Invalid download cable is used.
- Download cable is damaged.
- Connected target machine is not supported.
- Vijeo-Designer Runtime is not running or the target machine is not turned ON.
- You entered an incorrect IP address in the Target's download properties.
- The IP address set in the Target properties is not for a valid Vijeo-Designer target machine. You probably typed an IP address that belongs to other types of equipment.
- You used Download All on a project that has more than one target set to the same IP address.