How to uninstall Control Expert Version V14 ( former Unity Pro ) from your PC loaded with Windows 7 or Windows 10 Pro
Issue
Customer wants to uninstall the Control Expert Version V14 from his PC

Product Line
Control Expert V14 ( former Unity Pro )

Environment
Microsoft Windows 10 Pro
Version10.0.17134 Build 17134
or
Windows 7

Resolution
  1. Uninstall Control Expert V14.0 from control panel.
  2. In the computer delete the content of the following folders:
  • C:\ProgramData\Schneider Electric\Control Expert
  • C:\ProgramData\Schneider Electric\CommonControlExpert
  • C:\Program Files (x86)\Schneider Electric\Control Expert
  1. In the registry editor delete the following keys:
  • HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Schneider Electric\Control Expert
  • HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Schneider Electric\Control ExpertConfCatalog
  • HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Schneider Electric\Control ExpertTypesLibrary


Schneider Electric Netherlands

Ontdek meer
Productfamilie
Ontdek meer
Productfamilie
  • Productdocumentatie
  • Software & firmware
  • Productselector
  • Productvervanging
  • Help- en Contact Center
  • Offerte aanvragen?
  • Openingstijden & adressen
  • Vind distributeur
  • Schneider Electric-community
  • Werken bij
  • Bedrijfsprofiel
  • Wangedrag melden
  • Toegankelijkheid
  • Newsroom
  • Investeerders
  • EcoStruxure
  • Vacature zoeken
  • Blog
  • Als eerste op de hoogte nieuws?
  • Dataprivacy
  • Cookiekennisgeving
  • Juridische informatie
  • Change your cookie settings