Waarmee kunnen wij u vandaag helpen?

How to disable notification area features and virtual desktops from left and right swipe touch function on HMIP6?

On HMIP6xxxxx, to disable notification area features and virtual desktops from left and right swipe touch functions, We can open the Registry Editor, create a new Key named "EdgeUI" under "Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows", then create a new DWORD(32-BIT) Value named "AllowEdgeSwipe",if the value is 0, the function will be disabled, if the value is 1, the function will be enabled.

Please refer to the information in the following picture:

Schneider Electric Netherlands

  • Productdocumentatie
  • Software & firmware
  • Productselector
  • Productvervanging
  • Help- en Contact Center
  • Offerte aanvragen?
  • Openingstijden & adressen
  • Vind distributeur
  • Schneider Electric-community
  • Werken bij
  • Bedrijfsprofiel
  • Wangedrag melden
  • Toegankelijkheid
  • Newsroom
  • Investeerders
  • EcoStruxure
  • Vacature zoeken
  • Blog
  • Als eerste op de hoogte nieuws?
  • Dataprivacy
  • Cookiekennisgeving
  • Juridische informatie
  • Change your cookie settings