How can we help you today?

cable pull switches

Question
What is the difference between a “Normal Stop” and “Emergency Stop” versions of the XY2 cable pull switches?

Issue:
What is the difference between a “Normal Stop” and “Emergency Stop” versions of the XY2 cable pull switches?

Product Line:
Cable Pull Switches

Environment:
Machine Safety Products

Cause:
Product Selection

Resolution:
The Emergency stop versions have positive opening Normally Closed contacts that latch upon tripping (positive opening) and must be manually reset.

Normal stop versions are used where a momentary, non-emergency signal is required at any point along a cable. These devices have snap acting contacts and are non-latching devices.

Schneider Electric New Zealand

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Centre

Find support resources for all your needs, in one place.