Can all contact blocks be used for the 30mm range joysticks? [Video]

Question:
Can all contact blocks be used for the 30mm range joysticks?

Product String Reference:

  1. Top Level > Product Category > Industry > Industry Control & Drives > Control, Relays & Sign > Diameter 30.
  2. Top Level > PR_Product_OPS_Structure > Pushbuttons, Switches, Pilot Lights and Joysticks > 30mm Push Buttons > Harmony 30mm 9001K Metal Push Buttons

Objective:
The objective of this video is to provide an in-depth analysis of contact blocks and their application.



Product Line:
IDSIG - CONTROL, RELAYS & SIGN.

Environment:
N/A

Resolution:

When used in conjunction with a Harmony range push button, the:
  1. Combination N/O + N/C, N/C opens and N/O closes
  2. N/C contact opens when push button is depressed
  3. N/O contact closes when push button is depressed

When used in conjunction with the 30mm range joystick application.
  1. Combination N/O + N/C will stay open so that it is neither open nor closed
  2. N/C contact is open
  3. N/O contact is open
When the joystick is maneuvered, the:
  1. Combination N/O + N/C will close at different positions of the joystick handle.
  2. N/C will close
  3. N/O will close

As such, these contacts do not act in the same way for a joystick as they do for the Harmony range push button application.

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings