我们今天能为您提供什么帮助?

Alternatives to Play a Video in Machine SCADA Expert v2023

Issue:

This FAQ covers the alternatives available in Machine SCADA Expert v2023 to play a video.

Product:

EcoStruxure Machine SCADA Expert v2020, v2023

Environment:

HMI Configuration Software in Windows

Resolution:

To embed and play videos on a project screen in EcoStruxure Machine SCADA Expert, you have two main options:

1- ActiveX / .NET Controls

You can use native objects such as:

  • Web Browser
  • Windows Media Player
  • Or third-party objects like VNC.

Note: ActiveX controls are still supported in Machine SCADA Expert; however, we do not recommend using them anymore since modern alternatives like .NET controls or Custom Widgets are available.

2- Custom Widgets

In a Custom Widget, you can take advantage of HTML5 native compatibility to play videos, create video controls, or fully customize video playback.

ActiveX controls are still compatible with EMSE; however, we no longer recommend using them since modern options like .NET controls or Custom Widgets are available.

Additionally, if the project needs to be accessible to clients, Custom Widgets are the best option, as they make the object available on any web browser and platform through Mobile Access.

The Custom Widget Framework is required to execute Custom Widgets.

You can find the installation package here:

C:\Program Files (x86)\Schneider Electric\EcoStruxure Machine SCADA Expert 2023\Redist\CustomWidgetFramework

Modify video Settings:

1

If you need to hide video controls, proceed as follows:

2

When hovering the mouse over the video, no video controls appear:

3

Import the Widget:

You can copy the widget folder and reuse it in any project:

4

You can also use the .zip file included in this FAQ. Rename it to .cwp and copy it to the folder below:

C:\Program Files (x86)\Schneider Electric\EcoStruxure Machine SCADA Expert 2023\Redist\CustomWidgetsLibrary

5

Before opening it, adjust the width and height:

6

施耐德電機Taiwan

附件
CWVideoPlayer.zip [1.17 KB]
探索更多
系列:
探索更多
系列:

需要協助?

需要協助?

產品選型工具

產品選型工具

快速輕鬆地為您的應用找到合適的產品和附件。

取得報價

取得報價

立即線上提交您的銷售需求,專業團隊將主動聯繫您。

購買地點

購買地點

輕鬆在您所在地區找到最近的施耐德電機經銷商。

支援中心

支援中心

在同一位置找到滿足您所有需求的支援資源。

  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings