Issue: Replacement
Product Line: Lexium 05A
Environment: None
Cause: Obsolescence
Resolution:
The corresponding part number to replace a LXM05AD10M2 will be a LXM32AU90M2 in terms of current rating. Lexium 05A is a CanOpen drive and hence the direct option is to use a CanOpen drive. Some configuration changes at the drive and changes in the PLC program are to be expected. It may be better to understand the application to determine if a LXM32MU90M2 (modular drive with a different fieldbus module) or a LXM32CU90M2 standalone drive is a better alternative.
If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.
If you are not located in North America, please contact your local Customer Care Center for assistance:
Support | Schneider Electric Global (se.com)
Released for: Schneider Electric UK