Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
		
How can we help you today?
What sizes are available for the Altivar 630 and Altivar 930 Process drive?

Article available in these languages: SL

Issue:
Sizes for the Altivar 630 and Altivar 930 drives.

Product Line:
Altivar Process Drive (ATV630, ATV930)

Resolution:

Size 1

  • 208/240Vac
    • 0.75 – 4kW (1 - 5hp)
      • ATV630U07M3, ATV630U15M3,  ATV630U22M3, ATV630U30M3, ATV630U40M3
      • ATV930U07M3, ATV930U15M3,  ATV930U22M3, ATV930U30M3, ATV930U40M3
  • 400/460Vac
    • 0.75 – 5.5kW (1 - 7.5hp)
      • ATV630U07N4, ATV630U15N4, ATV630U15N4, ATV630U22N4, ATV630U30N4, ATV630U40N4, ATV630U55N4
      • ATV930U07N4, ATV930U15N4, ATV930U15N4, ATV930U22N4, ATV930U30N4, ATV930U40N4, ATV930U55N4

Size 2

  • 208/240Vac
    • 5.5kW (7.5hp)
      • ATV630U55M3
      • ATV930U55M3
  • 400/480Vac
    • 7.5 – 11kW (10 - 15hp)
      • ATV630U75N4, ATV630D11N4
      • ATV930U75N4, ATV930D11N4

Size 3

  • 208/240Vac
    • 7.5 – 11kW (10 - 15hp)
      • ATV630U75M3, ATV630D11M3
      • ATV930U75M3, ATV930D11M3
  • 400/480Vac
    • 15 – 22kW (20 - 30hp)
      • ATV630D15N4, ATV630D18N4, ATV630D22N4
      • ATV930D15N4, ATV930D18N4, ATV930D22N4

Size 4

  • 208/240Vac
    • 15 – 22kW (20 - 30hp)
      • ATV630D15M3, ATV630D18M3, ATV630D22M3
      • ATV930D15M3, ATV930D18M3, ATV930D22M3
  • 400/480Vac
    • 30 – 45kW (30 - 60hp)
      • ATV630D30N4, ATV630D37N4, ATV630D45N4
      • ATV630D30N4, ATV630D37N4, ATV630D45N4

Size 5

  • 208/240Vac
    • 30 – 45kW (40 - 60hp)
      • ATV630D30M3, ATV630D37M3, ATV630D45M3
      • ATV930D30M3(C), ATV930D37M3(C), ATV930D45M3(C)
  • 400/480Vac
    • 55 – 90kW (75 - 125hp)
      • ATV630D55N4, ATV630D75N4, ATV630D90N4
      • ATV930D55N4(C), ATV930D75N4(C), ATV930D90N4(C)

Size 6

  • 208/240Vac
    • 55 – 75kW (75 - 100hp)
      • ATV630D55M3, ATV630D75M3
      • ATV930D55M3C, ATV930D75M3C
  • 400/480Vac
    • 110 – 160kW (150 - 250hp)
      • ATV630C11N4, ATV630C13N4, ATV630C16N4
      • ATV930C11N4C, ATV930C13N4C, ATV930C16N4C

Size 7A

  • 400/480Vac
    • 220kW (350hp)
      • ATV630C22N4
      • ATV930C22N4(C)
      • Similar to Frame size 12 for the ATV61/71


Size 7B

  • 400/480Vac
    • 250 – 315kW (400 - 500hp)
      • ATV630C25N4, ATV630C31N4
      • ATV930C25N4C, ATV930C31N4C
      • Similar to Frame size 13 for the ATV61/71

Note:
"C" Suffix means it comes without a braking resistor.



drive atv630

drive size2 atv630

***

If this article does not answer your question, check out our FAQ database that has answers to more commonly asked questions: Frequently Asked Questions - Schneider Electric (se.com)

If this FAQ did not solve your issue, you can call us at 1-888-778-2733 Option 2 and then 4 or e-mail us at drive.products.support@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance: Support | Schneider Electric Global (se.com)

Schneider Electric UK

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings