Quantitative Analysis of a Prefabricated vs. Traditional Data Center

  • Document Number

    SPD_VAVR-9U4PPA_EN

  • Type

    White paper

  • Languages

    English

  • Date

    12/22/2015

  • Version

    V0

Download
  • Document Number

    SPD_VAVR-9U4PPA_EN

  • Type

    White paper

  • Languages

    English

  • Date

    12/22/2015

  • Version

    V0

Description:

Prefabricated modular data centers offer many advantages over traditionally built data centers, including flexibility, improved predictability, and faster speed of deployment. Cost , however, is sometimes stated as a barrier to deploying these designs. In this paper, we focus on quantifying the capital cost differences of a prefabricated vs. traditional 440 kW data center, both built with the same power and cooling architecture, in order to highlight the key cost drivers, and to demonstrate that prefabrication does not come at a capex premium . The analysis was completed and validated with Romonet’s Cloud-based Analytics Platform, a vendor-neutral industry resource.

Product Ranges:

Module Optimized Cooling, Power Skid, Chilled Water System, All-in-one container, Power Module, ...View more Module Optimized Cooling, Power Skid, Chilled Water System, All-in-one container, Power Module, All-in-one module, Prefabricated Data Hall ...View less

Files for Download

Add to my Documents

Description:

Prefabricated modular data centers offer many advantages over traditionally built data centers, including flexibility, improved predictability, and faster speed of deployment. Cost , however, is sometimes stated as a barrier to deploying these designs. In this paper, we focus on quantifying the capital cost differences of a prefabricated vs. traditional 440 kW data center, both built with the same power and cooling architecture, in order to highlight the key cost drivers, and to demonstrate that prefabrication does not come at a capex premium . The analysis was completed and validated with Romonet’s Cloud-based Analytics Platform, a vendor-neutral industry resource.

Product Ranges:

Module Optimized Cooling, Power Skid, Chilled Water System, All-in-one container, Power Module, All-in-one module, Prefabricated Data Hall

Files for Download

My Documents

Store, email, and share your favorite documents.

View My Documents
loader-lg loader-sm