Are EZM Main Circuit Breaker devices provided with lugs?

Issue:
Line Side Terminal configurations for EZM Mains

Product Line:
EZ Meter-Pak Metering Equipment - EZM

Resolution:
EZM Mains are available in one of two configuration styles, either being supplied with Factory Install Lugs, or configured with Lug Landings Pads and Mounting Hardware provided (Lugs are to be ordered separately).

EZM Mains Supplied with Factory Installed Line Side Lugs include:
Main Circuit Breakers                           Main Fusible Switch                         Main Lugs Tap Boxes
------                           ------                      ------                       ------              EZM1225TB          EZM3225TB
EZM1400CB            EZM3400CB            EZM1400FS         EZM3400FS       EZM1400TB          EZM3400TB
EZM1600CB            EZM3600CB            EZM1600FS         EZM3600FS       EZM1600TB          EZM3600TB
EZM1800CB            EZM3800CB            EZM1800FS         EZM3800FS       EZM1800TB          EZM3800TB
EZM11000CB          EZM31000CB                ------                      ------                  ------                       ------
EZM11200GCBT# EZM31200GCBT#          ------ ------                  ------                       ------
EZM11200JCBT# EZM31200JCBT# EZM11200FST# EZM31200FST#       ------                       ------
EZM11200GCBU*   EZM31200GCBU*     EZM11200FSB*     EZM31200FSB*       ------                       ------
EZM11200JCBU*    EZM31200JCBU*          ------                      ------                    ------                       ------
------                           ------                     ------                        ------              EZM11600TB         EZM31600TB
EZM11600GCBC      EZM31600GCBC        ------                        ------                  ------                       ------
EZM11600JCBC       EZM31600JCBC        ------                        ------                  ------                        ------
EZM12000CB          EZM32000CB             ------                        ------                  ------                        ------
# TOP Entry Only Main Device
*   Field Installable Lug Landing Kit (Cat. #: EZM1200ULL) is available. Requires that Lugs be ordered separately.

EZM Mains Supplied with NEMA Standard Lug Landing Pads with Mounting Hardware provided (Lugs are to be ordered separately) include:
Main Circuit Breakers                      Main Fusible Switch                          Main Lugs Tap Boxes
EZM1400CBU          EZM3400CBU         EZM1400FSU        EZM3400FSU        EZM1400TBU        EZM3400TBU
EZM1600CBU          EZM3600CBU         EZM1600FSU        EZM3600FSU        EZM1600TBU        EZM3600TBU
EZM1800CBU          EZM3800CBU         EZM1800FSU        EZM3800FSU        EZM1800TBU        EZM3800TBU
EZM11000CBU        EZM31000CBU             ------                       ------                       ------                       ------
------                      ------                       ------                       ------                EZM11200TBU      EZM31200TBU
EZM11200GCBE     EZM31200GCBE           ------                       ------                      ------                       ------
EZM11200JCBE      EZM31200JCBE      EZM11200FSE      EZM31200FSE            ------                       ------
EZM11600GCBU     EZM31600GCBU          ------                        ------                      ------                       ------
EZM11600JCBU     EZM31600JCBU          ------                        ------                      ------                       ------
EZM12000CBU       EZM32000CBU             ------                         ------               EZM12000TB         EZM32000TB

Schneider Electric USA

Explore more

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Center

Find support resources for all your needs, in one place.