How can we help you today?

Does the XCKJ10541 limit switch have a neutral position, or is it right or left motion only?

Issue:
Identify if the XCKJ10541 limit switch has a neutral position

Product Line:
Class XCK Limit Switches

Environment:
Square D Limit Switches

Resolution:
The ZCKE05 head can be programmed to be at rest in the center position, left, or right. Remove the head and change the programming with the black knob underneath. This is not a neutral position, where one set of contacts changes when the lever moves left, and the other set of contacts changes when the lever moves right of center. To obtain a neutral position switch, ZCKJ404 is the body and head combination that would support this.

Schneider Electric USA

Explore more
Product:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Product:
  • Help Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalog
  • Industries
  • Partners
  • Schneider Electric Community
  • Events
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings