How can we help you today?
What are the repair parts for an RC2M200S, series M01?
Issue:
Repair parts for RC2M200S Series M01.
Product Line:
CSED
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable that are still available:
Meter Cover Assembly - 4056206950
Main Breaker Section Cover Assembly - 4053449250
Main Breaker Section Cover Hinges - (2) X2983
Main Breaker Section Cover Hinge Mounting Screws - (2) 2159414081
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only 1 is required)
Dead Front Interior Trim Filler Plates - (2) QOFP
Meter Base Assembly - 4056250150 (includes meter base, (2) line side lugs, (4) meter jaws and meter jaw blade guides, (2) load side lugs (feeds QO base), and load side bussing (feeds QOM2-VH))
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Nuts - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Left Line Side Lug Assembly - 4056207850
Right Line Side Lug Assembly - 4056207950
Fifth Jaw Kit - 5J
Closing Cap - (2) ACP
Primary Main Breaker - QOM2-VH type, 200 A maximum
Main Breaker Mounting Nuts - (2) 2342702001
Secondary Main Breaker - QO-VH type, 50 A maximum
Main Breaker Mounting Base - 4050443650
Mounting Screw - 2196617201
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
Repair parts for RC2M200S Series M01.
Product Line:
CSED
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable that are still available:
Meter Cover Assembly - 4056206950
Main Breaker Section Cover Assembly - 4053449250
Main Breaker Section Cover Hinges - (2) X2983
Main Breaker Section Cover Hinge Mounting Screws - (2) 2159414081
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only 1 is required)
Dead Front Interior Trim Filler Plates - (2) QOFP
Meter Base Assembly - 4056250150 (includes meter base, (2) line side lugs, (4) meter jaws and meter jaw blade guides, (2) load side lugs (feeds QO base), and load side bussing (feeds QOM2-VH))
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Nuts - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Left Line Side Lug Assembly - 4056207850
Right Line Side Lug Assembly - 4056207950
Fifth Jaw Kit - 5J
Closing Cap - (2) ACP
Primary Main Breaker - QOM2-VH type, 200 A maximum
Main Breaker Mounting Nuts - (2) 2342702001
Secondary Main Breaker - QO-VH type, 50 A maximum
Main Breaker Mounting Base - 4050443650
Mounting Screw - 2196617201
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
Released for: Schneider Electric USA
Explore more
Category:
Explore more
Category:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.