Catalog number ZBZ160* is a metal guard for 40mm mushroom head operator.
ZBZ1600Chrome Plated
ZBZ1602Black
ZBZ1604Red
ZBZ1605Yellow
ZBZ1606Blue

Existing cap was damaged and needs to be replaced.  No, the cap is not removable and the entire operator needs to be replaced.

Not available in 277V LED, max is 240 volts.

Potentiometers are not supplied by Schneider Electric. They are customer supplied. Any electronics supply should have these.We only list that the ZB4BD922 is designed for potentiometers with a .25 inch shaft, the ZB4BD912 is designed for pots with a 6 mm shaft.

The difference is that the ZB4BV033S has a Fresnel (Jeweled) lens for better visibility, but both are for use with the Protected LED units.

Potentiometers are customer supplied.
They can be purchased at an electronics supply house. The operators are for potentiometers with a standard shaft length of 44 to 50 mm, and for the ZB4BD912 a shaft diameter of 6mm and for the ZB4BD922 a shaft diameter of 6.35mm.

Another option is to get the complete assembly (Operator + Potentiometer) Please see below for products part numbers.

+/- 10% linear mode precision complete potentiometer with screw terminals.

For METAL:
Resistance (k Ohms)WeightCatalog Number
10.095/0.209XB4BD912R1K
4.70.095/0.209XB4BD912R4K7
100.095/0.209XB4BD912R10K
470.095/0.209XB4BD912R47K
1000.095/0.209XB4BD912R100K
4700.095/0.209XB4BD912R470K


For PLASTIC:

Resistance (k Ohms)WeightCatalog Number
10.048/0.106XB5AD912R1K
4.70.048/0.106XB5AD912R4K7
100.048/0.106XB5AD912R10K
470.048/0.106XB5AD912R47K
1000.048/0.106XB5AD912R100K
4700.048/0.106XB5AD912R470K

Use a ZB4BZ2005 , ZB4BZ2105, or a ZBZ160* with cutout sides. Any of these will fit, however the padlocking feature will not work. These guards are made for the trigger action units, which are taller.

We do offer 10 kOhm pots in the 22 mm product line. For a plastic operator use reference: XB5AD912R10K OR for a metallic operator use reference: XB4BD912R10K

See attached for other Ohm resistances.

The ZBE101 and ZBE102 contact blocks can be used on the back of our selector switches, see the tables below to see what configurations can be achieved.
2 position selector switch
Left Side OperationRight Side OperationContact block guide
OX1 N.O. (left or right)
XO1 N.C. (left or right)
3 Position Selector Switch
Left Side OperationCenter OperationRight Side OperationContact Block Guide
OOX1 N.O. (left)
XOX2 N.O. wire in parallel (side by side)
XOO1 N.O. (right)
OXX1 N.C. (right)
XXO1 N.C. (left)
OXO2 N.C. wired in series (side by side)

* O indicates a contact being in the open state, X indicates a contact being in the closed state

A light module, mounting collar, and pilot light head will be needed to build up a complete pilot light module. Use the online selector tool to get the proper part numbers, you can find it here:https://www.se.com/us/en/work/support/resources-and-tools/calculators-and-online-tools/ez-selectors/

The difference is the number of parts in the packaging. TQ indicate bulk packaging.
ZBZ006C50 ( now : ZBZ006TQ ) - standard packaging qty. : 1000pcs
ZBZ006 -standard packaging qty. : 10pcs.

There are no illuminated E-stop mushroom heads that would work with BA9s light module. The ZB4BW643 or ZB5AT8643M push/pull and ZB5AW743 turn to release mushroom headpush button can only be used with protected LED light modules. The LED light module is only available from 12Vac/dc up to 240Vac.

XB4BS9445usesZB4BS944head that comes with Key No. 455
For a different key, replace with a completeZB4BS944** head.

See table below.
Complete PotentiometerResistance
XB4BD912R1K1 kΩ
XB4BD912R4K74.7 kΩ
XB4BD912R10K10 kΩ
XB4BD912R47K47 kΩ
XB4BD912R100K100 kΩ
XB4BD912R470K470 kΩ
XB5AD912R1K1 kΩ
XB5AD912R4K74.7 kΩ
XB5AD912R10K10 kΩ
XB5AD912R47K47 kΩ
XB5AD912R100K100 kΩ
XB5AD912R470K470 kΩ

The ZB4 series has padlock option.
Seethe attached catalog section with various options in 2 and 3 positions selector switches.

On a trigger action device you cannot depress the button and actuate the contacts without the button latching into the depressed position. Once the operator is depressed a certain amount it will latch into the depressed position and then actuate the contacts.

Use the following part numbers and specify text:
ZBY2002 is a 8 X 27 black legend with white letters and a 30 x 40 mm holder
ZBY2004 is a 8 X 27 red legend with white letters and a 30 x 40 mm holder
ZBY4001 is a 8 X 27 white legend with black letters and a 30 x 40 mm holder
ZBY4005 is a 8 X 27 yellow legend with black letters and a 30 x 40 mm holder.
Text is limited to 2 lines of 11 characters each.
Videos
Video: How to select a Harmony Push Button using the Product Selector?
Installing, operating and maintenance

No, this accessory is not forward compatible with the ZB4/ZB5 line of operators.Additionally, with the ZB4BH and ZB5AH push buttons the push-on / push-off mechanism was included in the operator.The same functionality is obtained.

This is a general wiring diagram for the BMXXBC280K, BMXXBC180K, BMXXBC120K, BMXXBC050K, BMXXBC030K, BMXXBC015K, BMXXBC008K.

When two push buttons are interlocked, only one button can be pushed at a time. We have interlock mechanism available on the Class 9001 pushbuttons. The interlock mechanism is not available on the XB4/XB5 units.

No. The mounting styles are incompatible. The ZB2BE contact blocks are screw mounted to mounting collar and the ZB4 contact blocks clip on the mounting collar with spring loaded clip.

For LED light modules
White  ZBV0113
Green  ZBV0133
Red   ZBV0143
Yellow  ZBV0153
Blue   ZBV0163
Clear  ZBV017

For BA9 light modules
White   ZBV011
Green  ZBV013
Red    ZBV014
Yellow  ZBV015
Blue   ZBV016
Clear  ZBV017
Mechanical operations for:
  • Push Button -- Spring return = 5 million, double headed = 1 million, push-push to release = 0.5 million
  • Selector Switch -- non-illuminated = 3 million, illuminated = 1 million
  • Toggle Switch = 0.5 million
  • Emergency stop push button = 0.3 million
  • Joystick = 1 million
  • Standard blocks = 5 million
  • Low power switching contact blocks = 0.5 million
  • 1 million total electrical operations.
NOTE: Product life is based on average usage under normal operating conditions.

It is unclear which contact blocks are used in 22mm control stations

The ZENL contact blocks are used in these control stations. These blocks mount directly to the control station itself and do notuse a mounting collar. A normally open contact block is ZENL1111, and a normally closed contact block is ZENL1121.These contact blocks are rated 10 amps max,AC-15 A600 and DC-15 R300.

Yes, remote V2 with firmware version 02-01-05-00 can be upgraded. See the attached instructions for details.

As of August 2017 our latest FW version for ZBRN1 is Ver1.5. Customer can do the update by themselves. you can get the FW update method and the new FW image file from attachment.

Product documentation and software
DC supply: Utilization category DC-13
Standard single or double blocks with screw clamp terminals:
Q600: Ue = 600 Vdc and le = 0.1 A or Ue = 250 Vdc and Ie = 0.27 A
or Ue = 125 Vdc and le = 0.55 A
Continuous Thermal Current = 2.5 A

The ZBZ58 is a Yellow bellows seal for a 22MM mushroom operator. It is similar to a boot function and prevents dust and other particles from enteringthe switch between the button operator shaft and the cylinder the shaft slides into.

The XB4 requires only 1 screw to tighten on the mounting collar verses 2 on the XB2. This allows easier installation. The XB4 push buttons can accept 3 contact blocks side-by-side-by-side for a total of nine contacts on non-illuminated devices. Using the XB4 Protected LED light modules and contacts on each side will allow shallower depth than the XB2 on illuminated devices.

How to Videos
Video: How to select a Harmony Push Button using the Product Selector?
Explore More
Products:Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
  • Help Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalog
  • Industries
  • Partners
  • Schneider Electric Community
  • Events
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings