What are the repair parts for an EZMR113225, Series M03 branch unit?
Issue:
current design repair parts
Product Line:
EZM Metering
Environment
repair parts
Cause:
maintenance
Resolution:
Only the parts listed below are considered field replaceable:
Customer Cover (includes labels) - EZM113225C
Cover Screws - 4020513002K
Meter Socket Cover (cover for one meter position) - MMRC
Spacer Cover above top meter cover position - EZM23TBKC
Parts Kit (one position, meter socket line side through tenant breaker base) - EZM1225KIT
Circuit Breaker RB Cover (one position) - BCV
Enclosure connecting hardware and Service Disconnect labels - 7329791750
Mounting Channel - 7329772401
Branch Neutral Lug assembly - 7329752253 (includes 3 lugs and the bus bar the lugs are mounted to)
Mounting screws and washer for Branch neutral lug assembly - 2159417241(1-screw required), 2159417121(1-screw required) and 2390331201(1-washer required)
Equipment Ground lug assembly - 7329897052 (includes 3 lugs and the mounting bracket)
Equipment Ground lug assembly mounting Screws - (2) 2142217101
End Closing Cap Kit - EZMCAP
End Closing Cap Kit (Right Side Only Shallow) - EZMSCAP
current design repair parts
Product Line:
EZM Metering
Environment
repair parts
Cause:
maintenance
Resolution:
Only the parts listed below are considered field replaceable:
Customer Cover (includes labels) - EZM113225C
Cover Screws - 4020513002K
Meter Socket Cover (cover for one meter position) - MMRC
Spacer Cover above top meter cover position - EZM23TBKC
Parts Kit (one position, meter socket line side through tenant breaker base) - EZM1225KIT
Circuit Breaker RB Cover (one position) - BCV
Enclosure connecting hardware and Service Disconnect labels - 7329791750
Mounting Channel - 7329772401
Branch Neutral Lug assembly - 7329752253 (includes 3 lugs and the bus bar the lugs are mounted to)
Mounting screws and washer for Branch neutral lug assembly - 2159417241(1-screw required), 2159417121(1-screw required) and 2390331201(1-washer required)
Equipment Ground lug assembly - 7329897052 (includes 3 lugs and the mounting bracket)
Equipment Ground lug assembly mounting Screws - (2) 2142217101
End Closing Cap Kit - EZMCAP
End Closing Cap Kit (Right Side Only Shallow) - EZMSCAP
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.