What are the repair parts for the RC1624M125S, series M01?
Issue:
Repair parts
Product Line:
CSED
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056172350 (includes latch)
Load Center Cover - 7329401401
Load Center Cover Hinges - (2) X2983
Load Center Cover Hinge Mounting Screws (2) 2159414081
Dead Front Interior Trim - 4056168402
Dead Front Interior Trim Mounting Screw - 4020513001K (this kit contains 10 screws; only one screw is required to secure the interior trim)
Load Center Interior - 4056170150 (does not include main breaker)
Load Center Interior Mounting Screws - (9) 2153217161
Main Breaker - HOM2125
Meter Base Assembly - 4056223250 (includes meter base with the right, load side meter jaw, blade guide, and L-shaped connector assembled to the meter base)
Meter Jaw - (3) 7329794850 (fourth is included in the meter base assembly, noted above)
Meter Jaw Mounting Bolt - (3) 2271020242 (fourth is included in the meter base assembly, noted above)
Meter Jaw Mounting Keps Nut - (3) 2342702001 (fourth is included in the meter base assembly, noted above)
Meter Jaw Blade Guide - (3) 4052761901 (fourth is included in the meter base assembly, noted above)
Line Side Phase Lugs - (2) 4025102451
Line Side Phase Lugs Mounting Bolt - (2) 2271020242
Line Side Phase Lugs Mounting Keps Nut - (2) 2342702001
Line Side Neutral Lug - LK100AN
Closing Plate - (2) ACP
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Repair parts
Product Line:
CSED
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056172350 (includes latch)
Load Center Cover - 7329401401
Load Center Cover Hinges - (2) X2983
Load Center Cover Hinge Mounting Screws (2) 2159414081
Dead Front Interior Trim - 4056168402
Dead Front Interior Trim Mounting Screw - 4020513001K (this kit contains 10 screws; only one screw is required to secure the interior trim)
Load Center Interior - 4056170150 (does not include main breaker)
Load Center Interior Mounting Screws - (9) 2153217161
Main Breaker - HOM2125
Meter Base Assembly - 4056223250 (includes meter base with the right, load side meter jaw, blade guide, and L-shaped connector assembled to the meter base)
Meter Jaw - (3) 7329794850 (fourth is included in the meter base assembly, noted above)
Meter Jaw Mounting Bolt - (3) 2271020242 (fourth is included in the meter base assembly, noted above)
Meter Jaw Mounting Keps Nut - (3) 2342702001 (fourth is included in the meter base assembly, noted above)
Meter Jaw Blade Guide - (3) 4052761901 (fourth is included in the meter base assembly, noted above)
Line Side Phase Lugs - (2) 4025102451
Line Side Phase Lugs Mounting Bolt - (2) 2271020242
Line Side Phase Lugs Mounting Keps Nut - (2) 2342702001
Line Side Neutral Lug - LK100AN
Closing Plate - (2) ACP
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Released for: Schneider Electric USA
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.