What are the repair parts for the RC816D200CH, series 002?
Issue:
Repair parts
Product Line:
CSED
Resolution:
Rainproof Cap - 4056115803
Rainproof Cap Mounting Screws - (2) 2142717161
Meter Cover Assembly - 4056143052 (includes latch)
Load Center Cover Assembly - 4056128052 (includes hinges)
Load Center Cover Mounting Rivet - (4) 2430315290
Dead Front Interior Trim - 4056114503
Dead Front Interior Trim Mounting Screw - 4020513001K (this kit contains 10 screws, but only one is required to mount the interior trim)
Load Center Interior - 4056133352 (does not include main breaker or secondary main breaker mounting base; includes feed-thru lugs)
Load Center Interior Mounting Screws - (7) 2153217161
Main Breaker - HOM2200
Main Breaker Retaining Hardware - 4056132701 (hold down strap that straddles across the main breaker), 4056152501 (clamp), 4056152601 (spacer), and 2159417721 (screw)
Feed-Thru Phase Lug Assembly (Left) - 4056133252
Feed-Thru Phase Lug Assembly (Right) - 4056133152
Feed-Thru Phase Lug Assemblies Mounting Keps Nut - (2) 2342702000
Feed-Thru Neutral/Ground Lug - 4025114550 (double barrel lug)
Feed-Thru Neutral/Ground Lug Mounting Nut - 2342702200
Secondary Main Breaker Base Assembly- 4055841752
Secondary Main Breaker Base Assembly Mounting Screws - 2153217161
Meter Base Assembly - 4056149752 (includes load side lugs, meter jaws, and horn bypasses; does not include load side meter jaw blade guides)
Meter Jaw - (2) 7329794850 (load side meter jaws are included in the meter base assembly)
Meter Jaw Mounting Keps Nut - (2) 2342702001 (load side meter jaw mounting keps nuts are included in the meter base assembly)
Meter Jaw Blade Guide - (4) 4052761901
Fifth Jaw Assembly - 4052729550
Fifth Jaw Assembly Mounting Screw - 2153217161
Line Side Horn Bypass - (2) 4056150901 (line side horn bypasses are included in the meter base assembly)
Line Side Phase Lugs - (2) 4025116051
Line Side Phase Lugs Mounting Carriage Bolts - (2) 2271020242
Line Side Phase Lugs Mounting Keps Nuts - (2) 2342702000
Line Side Neutral Lugs - (2) 4025116051
Line Side Neutral Lugs Mounting Keps Nuts - (2) 2342702000
Service Ground Lug - 4025102451
Service Ground Lug Mounting Keps Nut - 2342702001
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Repair parts
Product Line:
CSED
Resolution:
Rainproof Cap - 4056115803
Rainproof Cap Mounting Screws - (2) 2142717161
Meter Cover Assembly - 4056143052 (includes latch)
Load Center Cover Assembly - 4056128052 (includes hinges)
Load Center Cover Mounting Rivet - (4) 2430315290
Dead Front Interior Trim - 4056114503
Dead Front Interior Trim Mounting Screw - 4020513001K (this kit contains 10 screws, but only one is required to mount the interior trim)
Load Center Interior - 4056133352 (does not include main breaker or secondary main breaker mounting base; includes feed-thru lugs)
Load Center Interior Mounting Screws - (7) 2153217161
Main Breaker - HOM2200
Main Breaker Retaining Hardware - 4056132701 (hold down strap that straddles across the main breaker), 4056152501 (clamp), 4056152601 (spacer), and 2159417721 (screw)
Feed-Thru Phase Lug Assembly (Left) - 4056133252
Feed-Thru Phase Lug Assembly (Right) - 4056133152
Feed-Thru Phase Lug Assemblies Mounting Keps Nut - (2) 2342702000
Feed-Thru Neutral/Ground Lug - 4025114550 (double barrel lug)
Feed-Thru Neutral/Ground Lug Mounting Nut - 2342702200
Secondary Main Breaker Base Assembly- 4055841752
Secondary Main Breaker Base Assembly Mounting Screws - 2153217161
Meter Base Assembly - 4056149752 (includes load side lugs, meter jaws, and horn bypasses; does not include load side meter jaw blade guides)
Meter Jaw - (2) 7329794850 (load side meter jaws are included in the meter base assembly)
Meter Jaw Mounting Keps Nut - (2) 2342702001 (load side meter jaw mounting keps nuts are included in the meter base assembly)
Meter Jaw Blade Guide - (4) 4052761901
Fifth Jaw Assembly - 4052729550
Fifth Jaw Assembly Mounting Screw - 2153217161
Line Side Horn Bypass - (2) 4056150901 (line side horn bypasses are included in the meter base assembly)
Line Side Phase Lugs - (2) 4025116051
Line Side Phase Lugs Mounting Carriage Bolts - (2) 2271020242
Line Side Phase Lugs Mounting Keps Nuts - (2) 2342702000
Line Side Neutral Lugs - (2) 4025116051
Line Side Neutral Lugs Mounting Keps Nuts - (2) 2342702000
Service Ground Lug - 4025102451
Service Ground Lug Mounting Keps Nut - 2342702001
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Released for: Schneider Electric USA
Explore more
Category:
Explore more
Category:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.