How can we help you today?
What are the repair parts for an RC816F200C, Series M01?
Issue:
Repair parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056167850 (includes latch)
Load Center Cover - 4056157550 (includes hinges and latch)
Load Center Cover Mounting Screws - (4) 2159417121
Dead Front Interior Trim - 4056173401
Dead Front Interior Trim Mounting Screws - 4020513001K (contains 10 screws; only 2 screws are required to mount the interior trim)
Load Center Interior - 4056161950 (main breaker not included; feed thru lugs included)
Load Center Interior Mounting Screws - (4) 2153217161
Main Breaker - QOM2200VH
Main Breaker Mounting Hardware - (2) 2342702001 keps nuts and (1) 4020511201 screw
Meter Base Assembly - 4056190150 (includes meter base, line side lugs, line and load side meter jaws, line and load side meter jaw blade guides, and load side connectors)
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Keps Nuts - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Repair parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056167850 (includes latch)
Load Center Cover - 4056157550 (includes hinges and latch)
Load Center Cover Mounting Screws - (4) 2159417121
Dead Front Interior Trim - 4056173401
Dead Front Interior Trim Mounting Screws - 4020513001K (contains 10 screws; only 2 screws are required to mount the interior trim)
Load Center Interior - 4056161950 (main breaker not included; feed thru lugs included)
Load Center Interior Mounting Screws - (4) 2153217161
Main Breaker - QOM2200VH
Main Breaker Mounting Hardware - (2) 2342702001 keps nuts and (1) 4020511201 screw
Meter Base Assembly - 4056190150 (includes meter base, line side lugs, line and load side meter jaws, line and load side meter jaw blade guides, and load side connectors)
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Keps Nuts - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.