How can we help you today?
How can calibration of the S33595 be checked?
Product Line:
Circuit Breaker
Resolution:
The calibration of the test set is checked each time it is used. The S33595 microprocessor is designed with a power-up self check sequence. Each time the unit is powered up, it does a self diagnostic. This checks the health of all electronics, as well as positions of relays and switches inside the test kit. The self diagnostic also checks communications to the screen and the voltage level supplying the test kit. The test kit will not proceed to the test screens until all of these are verified.
The test kit also looks at calibration before each secondary injection test and if the microprocessor determines that it cannot reliably inject the correct signal, an error message will appear on the screen "Test kit calibration error, Test aborted". When this occurs, the test kit must be replaced with the new LV485500 Service interface kit.
For more details see instruction bulletin for the FFTK:
https://www.se.com/us/en/download/document/48049-183-06/
NOTE: The Service interface kit LV485500 must be used with PC running the EcoStruxure Power Commission software and the Circuit breaker advanced testing license.
See the LV485500 user guide for more information
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.