What are the repair parts for an SC1624M125S, series M01?
Issue:
Current design repair parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056161350
Meter Cover Mounting Screws - 4020513002K (contains 10 screws; only 2 screws required)
Meter Sealing Ring - 2920910001
Utility Pullbox Cover - 4056172250 (includes latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover - 7329401401
Load Center Cover Hinges - (2) X2983
Load Center Cover Hinge Mounting Screws (2) 2159414081
Dead Front Interior Trim - 4056168402
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only 1 screw required)
Load Center Interior - 4056170150 (main breaker not included)
Load Center Interior Mounting Screws - (9) 2153217161
Main Breaker - HOM2125
Meter Base Assembly - 4056223250 (includes meter base with the right, load side meter jaw, blade guide, and L-shaped connector assembled to the meter base)
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Bolt - (4) 2271020242
Meter Jaw Mounting Keps Nut - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Line Side Phase Lugs - (2) 4025102451
Line Side Phase Lugs Mounting Bolt - (2) 2271020242
Line Side Phase Lugs Mounting Keps Nut - (2) 2342702001
Line Side Neutral Lug - LK100AN
Closing Plate - (2) ACP
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Current design repair parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field replaceable:
Meter Cover - 4056161350
Meter Cover Mounting Screws - 4020513002K (contains 10 screws; only 2 screws required)
Meter Sealing Ring - 2920910001
Utility Pullbox Cover - 4056172250 (includes latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover - 7329401401
Load Center Cover Hinges - (2) X2983
Load Center Cover Hinge Mounting Screws (2) 2159414081
Dead Front Interior Trim - 4056168402
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only 1 screw required)
Load Center Interior - 4056170150 (main breaker not included)
Load Center Interior Mounting Screws - (9) 2153217161
Main Breaker - HOM2125
Meter Base Assembly - 4056223250 (includes meter base with the right, load side meter jaw, blade guide, and L-shaped connector assembled to the meter base)
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Bolt - (4) 2271020242
Meter Jaw Mounting Keps Nut - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Line Side Phase Lugs - (2) 4025102451
Line Side Phase Lugs Mounting Bolt - (2) 2271020242
Line Side Phase Lugs Mounting Keps Nut - (2) 2342702001
Line Side Neutral Lug - LK100AN
Closing Plate - (2) ACP
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.